Adenovirus Respiratory
Antigen Rapid Test
High-specificity lateral flow immunochromatographic assay for the direct qualitative identification of human Adenovirus hexon antigen from nasopharyngeal swabs, nasal swabs, or aspirates. Delivers reliable visual diagnostic confirmation in 15 minutes to distinguish adenoviral infection from bacterial pharyngitis and seasonal influenza.
Rapid Etiologic Discrimination in Acute Upper & Lower Respiratory Illness
Adenovirus causes severe outbreaks of pharyngitis, croup, bronchitis, and viral pneumonia, especially in daycare centers, schools, and military cohorts. Rapid testing immediately halts unnecessary antibiotic therapy.
Broad Serotype Coverage
Features specific monoclonal antibodies reactive against the group-specific hexon protein shared across common respiratory serotypes (1, 2, 3, 4, 5, 7, 14, and 21), ensuring complete diagnostic capture.
- Detects all major respiratory serotypes
- Calibrated for pediatric mucosal titers
- No false-positive cross-binding
100% Sensitivity in Clinical Trials
Demonstrated 100% clinical sensitivity and 99.40% specificity in multi-center clinical trials compared directly against gold-standard RT-PCR assays, eliminating diagnostic uncertainty.
- 100.0% Sensitivity (95% CI: 95.6%–100%)
- 99.40% Specificity (95% CI: 96.5%–99.9%)
- 99.50% Overall diagnostic agreement
No Cold Chain Logistics
Stable at 2°C to 30°C with a 24-month shelf life. Pre-filled extraction buffer tubes and sterile swabs ensure frictionless point-of-care implementation across clinics in Dubai and the UAE.
- Ambient storage: 2°C – 30°C
- 24-Month manufacturer shelf life
- Complete kit with pre-filled dropper tubes
Multi-Center Clinical Evaluation (vs. RT-PCR Reference)
CE-IVD Clinical Trial Cohort (n = 480)| Diagnostic Parameter | Clinical Result | 95% Confidence Interval (CI) | Clinical Significance |
|---|---|---|---|
| Clinical Sensitivity | 100.0% | 95.6% – 100.0% | Complete positive agreement across all acute clinical presentations |
| Clinical Specificity | 99.40% | 96.5% – 99.9% | Near-perfect negative agreement avoids misdiagnosis in viral co-infections |
| Overall Diagnostic Accuracy | 99.50% | 97.8% – 99.9% | High concordance across pediatric, adult, and immunocompromised cohorts |
| Limit of Detection (LoD) | 1.0 x 10³ TCID50/mL | Analytical LoD Protocol | Reliably detects low-titer viral concentrations in nasopharyngeal secretions |
| Cross-Reactivity | 0.0% Non-Reactive | Panel of 24 Pathogens | Zero cross-reactivity with SARS-CoV-2, Flu A, Flu B, RSV, or Rhinovirus |
4-Step Standard Operating Procedure
Instrument-free clinical workflow designed for fast deployment in outpatient clinics and emergency departments.
Specimen Collection
Collect nasopharyngeal secretions via sterile flocked swab or obtain a nasal wash/aspirate specimen from the patient using standard aseptic technique.
Lysis & Extraction
Insert the swab into the pre-filled extraction buffer tube. Rotate the swab head against the tube walls 10 times while squeezing the flexible tube sides.
Sample Inoculation
Fit the dropper nozzle securely onto the tube. Invert vertically and dispense exactly 3 full drops (80 µL) of extract into sample well (S) of the cassette.
Result Readout
Read chromatographic results at exactly 15 minutes. Strong positive lines may appear earlier, but negative results must be verified at 15 minutes. Do not interpret past 20 minutes.
Visual Result Interpretation Guide
Rapid, intuitive colorimetric line reading provides unambiguous answers at bedside.
Definitive Test Outcomes
Evaluation of colored bands formed in the reading window:
Clinical Diagnostic Best Practices
Key considerations for healthcare practitioners:
Everything Required for Point-of-Care Adenovirus Testing
Supplied in clinical boxes of 25 tests, fully equipped for point-of-care operation without additional consumables.
Complementary Respiratory Rapid Test Kits
Expand your clinic's triage capabilities with complementary lateral flow rapid assays from QuRapid.
COVID-19 & Influenza A+B Combo Rapid Test
View Test Details →Influenza A+B Antigen Rapid Test
View Test Details →COVID-19 Antigen Rapid Test (Professional)
View Test Details →RSV Antigen Rapid Test
View Test Details →Frequently Asked Questions
Need validation dossiers, regulatory certificates, or bulk clinic pricing? Contact our clinical team in Dubai.
Contact Clinical SpecialistWhich Adenovirus serotypes does this rapid test detect?
The assay incorporates high-affinity monoclonal antibodies targeting the conserved hexon capsomer antigen shared across all prevalent human respiratory Adenovirus serotypes, including types 1, 2, 3, 4, 5, 7, 14, and 21.
What is the time required for conclusive results?
Clear visual test lines develop within 15 minutes. Positive results with high viral antigen concentrations may appear within 3 to 5 minutes, while negative results must be verified at the full 15-minute incubation period.
What specimens are validated for clinical collection?
The test is CE-IVD validated for human nasopharyngeal swabs, nasal swabs, and nasal wash/aspirate specimens collected using sterile medical swabs.
What is the analytical sensitivity (Limit of Detection)?
The analytical limit of detection is 1.0 x 10³ TCID50/mL, ensuring high clinical detection even during the early mucosal viral shedding phase.
Does this test cross-react with other respiratory viruses?
No. Comprehensive cross-reactivity studies have confirmed 0.0% cross-reactivity with SARS-CoV-2, Influenza A, Influenza B, RSV, Parainfluenza types 1-4, Human Metapneumovirus, and Rhinovirus.
Equip Your Clinic With QuRapid Adenovirus Rapid Antigen Tests
Order CE-IVD certified Adenovirus Respiratory Rapid Test Kits with same-day dispatch across Dubai, Abu Dhabi, and the UAE. Wholesale volume pricing available for hospitals, pediatric clinics, and emergency triage centers.