Optimization
CE-IVD Certified Lateral Flow Immunoassay

Influenza A+B
Antigen Rapid Test

Rapid qualitative differentiation of Influenza Type A and Influenza Type B nucleoprotein antigens from a single nasopharyngeal or nasal swab. Delivers clear, visual A/B-specific results in 15 minutes to initiate targeted antiviral therapy immediately.

Readout Time 15 Minutes
Specimen Type NP / Nasal Swab
Clinical Sensitivity 99.1% (Flu A) | 97.6% (Flu B)
Storage / Shelf Life 2°C – 30°C (24 Mos)
QuRapid Flu A+B Device CE-IVD Marked
Influenza A+B Reading Window
S
C — Control Line
A — Influenza Type A
B — Influenza Type B
Differential POC Diagnosis

Why Rapid Flu A/B Differentiation Matters

Influenza A and B share near-identical early symptom presentations — acute fever, myalgia, cough, and malaise — making clinical differentiation by physical examination alone unreliable. Rapid A/B discrimination enables targeted antiviral prescribing within the narrow therapeutic window.

Influenza Type A

Influenza A

The predominant driver of seasonal epidemics and pandemic outbreaks. Type A viruses infect humans and animals, undergoing rapid antigenic drift. The conserved nucleoprotein (NP) antigen enables detection across all circulating strains including H1N1 and H3N2.

  • Clinical Sensitivity: 99.1% (H1N1 pdm09)
  • Clinical Specificity: 99.3% vs. RT-PCR
  • Covers all seasonal Influenza A subtypes
Influenza Type B

Influenza B

Circulates exclusively in humans and causes significant morbidity in pediatric and elderly populations. Both Yamagata and Victoria lineages are detectable. Guiding baloxavir or oseltamivir therapy requires confirmed Type B identification.

  • Clinical Sensitivity: 97.6% (Victoria lineage)
  • Clinical Specificity: 99.1% vs. RT-PCR
  • Covers both B/Yamagata and B/Victoria lineages
UAE Seasonality

Gulf Region Patterns

In the UAE and GCC, influenza activity peaks November–February and June–August. Year-round vigilance is critical given high-volume international travel corridors and the diverse expatriate population across major urban hubs.

  • Nov–Feb Primary Influenza Season
  • Jun–Aug Secondary Activity Period
  • Year-round POC surveillance recommended

Clinical Performance vs. RT-PCR Reference Method

Multicenter Trial Validated
Analyte / Virus Clinical Sensitivity (95% CI) Clinical Specificity (95% CI) Total Agreement Limit of Detection (LoD)
Influenza A (H1N1 pdm09) 99.1% (95.4% – 99.8%) 99.3% (98.1% – 99.8%) 99.2% 1.5 × 103 TCID50/mL
Influenza A (H3N2) 98.4% (94.2% – 99.6%) 99.3% (98.1% – 99.8%) 98.9% 1.5 × 103 TCID50/mL
Influenza B (Victoria) 97.6% (92.8% – 99.3%) 99.1% (97.8% – 99.7%) 98.5% 1.5 × 103 TCID50/mL
Influenza B (Yamagata) 96.8% (91.2% – 98.9%) 99.1% (97.8% – 99.7%) 98.2% 2.0 × 103 TCID50/mL
* Zero cross-reactivity confirmed with SARS-CoV-2, RSV, Human Adenovirus, Rhinovirus, Parainfluenza types 1–4, Human Metapneumovirus, Streptococcus pneumoniae, and Mycoplasma pneumoniae. Samples tested within 5 days of symptom onset.
Standard Operating Procedure

Simple 4-Step Clinic Protocol

Engineered for busy outpatient triage, urgent care centers, and clinical laboratories with no specialized instrumentation required.

1

Collect Swab

Collect a nasopharyngeal or anterior nasal specimen using the sterile flocked swab supplied with the test kit. Collect within 5 days of symptom onset for optimal viral yield.

2

Extract Antigen

Insert swab into the pre-filled extraction buffer tube. Rotate 10–12 times against the tube wall. Squeeze tube sides while withdrawing. Attach dropper nozzle cap.

3

Dispense Drops

Hold dropper vertically and dispense exactly 3 drops (≈80 μL) into the cassette sample well (S). Begin timing immediately after dispensing.

4

Read at 15 Min

Interpret visual bands at the 15-minute mark. Results must not be read after 20 minutes to prevent chromatographic false readings.

Band Interpretation Guide

How to Read the Influenza A+B Test Lines

The single reading window contains three lines: C (Control), A (Influenza Type A), and B (Influenza Type B). The control line must always appear for a valid result, regardless of the test outcome.

Positive Results — Influenza Detected

Any visible colored band at line A or B, with C visible, indicates a positive result.

Influenza A Positive
Lines visible at (C) and (A). No band at (B).
Influenza B Positive
Lines visible at (C) and (B). No band at (A).
Flu A + B Co-infection
Lines visible at (C), (A), and (B) simultaneously.

Negative & Invalid Results

Absent A and B lines with visible C indicates no detectable antigen. Missing C line invalidates the test.

Negative — No Flu Detected
Line (C) only. Neither (A) nor (B) appears.
Invalid Test
No line at (C). Discard & retest with a new kit.
Clinical Note
Negative does not exclude early-stage infection. Repeat if clinical suspicion remains high.
Kit Specifications

What’s Included in Each Kit (25 Tests/Box)

📦 25 Test Cassettes Individually sealed foil pouches with desiccant
🧪 25 Pre-filled Tubes Pre-dispensed extraction buffer with dropper nozzles
🩸 25 Sterile Swabs Flocked nasal/nasopharyngeal swabs
📋 Package Insert (IFU) Complete instructions & quality control protocol
Clinical Support

Frequently Asked Questions

Need technical information, validation dossiers, or regulatory certificates? Contact our clinical diagnostic team in Dubai.

Contact Clinical Specialist
Can this test differentiate between Influenza A and B?

Yes. The test features distinct, physically separated test lines for Influenza A (line A) and Influenza B (line B) in the single reading window, allowing clear, unequivocal differentiation between the two seasonal viral strains in 15 minutes.

Can this test distinguish between Influenza A subtypes (H1N1 vs H3N2)?

No — the assay detects the conserved nucleoprotein (NP) antigen shared across all Influenza A strains. Both H1N1 (pdm09) and H3N2 produce a positive A line. Subtype identification requires RT-PCR or next-generation sequencing.

How early after symptom onset should the test be performed?

Testing is optimal within the first 1 to 5 days after symptom onset when viral shedding in upper respiratory secretions is at its peak. Beyond day 7, viral shedding may decrease below the assay’s limit of detection.

Does this test cross-react with other common respiratory viruses?

Extensive multicenter validation has confirmed zero cross-reactivity with SARS-CoV-2, RSV, Human Adenovirus, Rhinovirus, Parainfluenza types 1–4, Human Metapneumovirus, Streptococcus pneumoniae, and Mycoplasma pneumoniae.

What are the storage requirements and shelf life?

Store sealed in the original packaging at 2°C to 30°C. No cold chain logistics required, provided ambient temperatures remain strictly below 30°C. Shelf life is 24 months from manufacture date.

Equip Your Clinic With QuRapid Influenza A+B Rapid Tests

Order CE-IVD Influenza A+B Antigen Rapid Test Kits with same-day dispatch across Dubai, Abu Dhabi, and the UAE. B2B bulk pricing available for hospitals, clinics, and government health authorities.

Request Quotation