Optimization
WHO-Recommended Malaria Differential Cassette

Malaria Pf / Pan
Rapid Test

Rapid lateral flow chromatographic immunoassay for the qualitative detection and differentiation of Plasmodium falciparum Histidine-Rich Protein II (HRP-2) and Pan-malarial Lactate Dehydrogenase (pLDH) in human whole blood. Results in 10 to 15 minutes.

Readout Time 10 – 15 Minutes
Specimen Type Capillary / Venous Blood
Overall Accuracy 99.4% Agreement
Storage / Shelf Life 2°C – 30°C (24 Mos)
QuRapid Malaria Pf/Pan Device CE-IVD Marked
Malaria Differential Window (Pf / Pan)
S
B
C: Procedural Control Line
Pf: Plasmodium falciparum (HRP-2)
Pan: Conserved Lactate Dehydrogenase (pLDH)
Parasitological Differentiation

Rapid Discrimination of Lethal Falciparum vs. Non-Falciparum Strains

Plasmodium falciparum causes cerebral malaria and acute life-threatening multi-organ distress requiring immediate Artemisinin-based Combination Therapy (ACT). In contrast, non-falciparum species require specific hypnozoitocidal regimens (Primaquine/Tafenoquine). Point-of-care differential diagnosis guides lifesaving antimalarial regimens.

Lethal Pathogen

Plasmodium falciparum (HRP-2)

Detects Histidine-Rich Protein II, a water-soluble antigen produced in high volume by asexual intraerythrocytic stages of P. falciparum.

  • Immediate cerebral malaria risk alert
  • Directs urgent first-line ACT chemotherapy
  • High analytical sensitivity (50 parasites/µL)
Pan-Malarial Target

Pan pLDH (Vivax / Ovale / Malariae)

Targets conserved pan-malarial lactate dehydrogenase enzyme expressed across all human plasmodium species during active parasitemia.

  • Detects P. vivax, P. malariae, and P. ovale
  • Enables relapse prevention therapy
  • Active parasitemia marker (>99.9% sensitivity)
UAE Travel Health

Emergency Bedside Triage

Dubai is a premier international air transit and maritime logistics hub with regular passenger transit from malaria-endemic zones in Africa and South Asia.

  • Instant 10–15 min triage for febrile travelers
  • Fingerstick blood sampling at bedside
  • Pre-cleared CE-IVD regulatory compliance

Analytical & Clinical Validation vs. Microscopy & PCR

Multi-Center Clinical Evaluation (n=850)
Diagnostic Parameter Plasmodium falciparum (Pf) Pan Species (Vivax/Ovale/Malariae) Overall Clinical Agreement
Clinical Sensitivity >99.9% (95% CI: 96.5% – 100%) >99.9% (95% CI: 93.3% – 100%) >99.9%
Clinical Specificity 99.1% (95% CI: 96.7% – 99.9%) 99.1% (95% CI: 96.7% – 99.9%) 99.1%
Total Diagnostic Accuracy 99.4% (95% CI: 98.0% – 99.9%) 99.4% (95% CI: 98.0% – 99.9%) 99.4%
Limit of Detection (LOD) 50 parasites / µL blood 100 parasites / µL blood WHO RDT Benchmark Exceeded
*Clinical evaluations conducted against reference Giemsa-stained thin/thick blood film microscopy and confirmatory nested PCR in accordance with WHO malaria RDT testing standards.
Standard Operating Procedure

4-Step Bedside Protocol for Whole Blood Triage

Engineered for immediate point-of-care execution in emergency departments, intensive care units, and fever clinics without laboratory centrifugation.

1

Blood Harvesting

Clean puncture site with alcohol swab. Prick fingertip with sterile lancet and collect exactly 5 µL of capillary whole blood using the mini capillary dropper.

2

Sample Inoculation

Transfer the 5 µL of whole blood directly into the circular sample well (S) of the cassette, ensuring complete expulsion without air bubbles.

3

Lysis Buffer Addition

Add 2 to 3 drops of lysis buffer into the buffer well (B). The buffer rapidly hemolyzes red blood cells and releases parasitic antigens across the test strip.

4

Visual Interpretation

Read diagnostic lines between 10 and 15 minutes under standard clinical lighting. Do not interpret or record results after 20 minutes.

Visual Readout Guide

Diagnostic Interpretation Matrix

Direct visual line differentiation for immediate clinical decision-making and antimalarial prescription.

Positive Differential Findings

Appearance of the Control line (C) alongside Pf and/or Pan test lines.

P. falciparum Positive (C + Pf)
Pf band present (Pan may also show). Severe malaria protocol.
Non-Falciparum Positive (C + Pan)
Pan band only. P. vivax, P. ovale, or P. malariae infection.
Mixed Infection (C + Pf + Pan)
Dual infection (P. falciparum + non-falciparum species).

Negative & Invalid Results

Quality control validation and procedural guidelines.

Negative (C Line Only)
Only C line visible; no Pf or Pan bands. No parasitemia detected.
Invalid (No C Line)
Absence of Control line indicates insufficient volume or faulty strip. Retest.
Packaging & Accessories

Everything Included in the Kit Box

Each professional diagnostic kit comes complete with all sterile collection disposables and reagents for 25 tests.

💊 25 Test Cassettes Individually sealed in foil pouches with desiccant
🖊 25 Transfer Droppers Calibrated mini capillary pipettes for 5 µL whole blood
🧪 Lysis Buffer Bottle Optimized erythrocyte lysis and antigen mobilization buffer
📄 Instructions for Use Comprehensive CE-IVD package insert & SOP protocol
Clinical Support

Frequently Asked Questions

Need validation dossiers, regulatory certificates, or bulk clinic pricing? Contact our parasitology diagnostic specialists in Dubai.

Contact Clinical Specialist
Which malaria species does the Pan line detect?

The Pan line targets conserved pan-malarial lactate dehydrogenase (pLDH), detecting all four major human malaria species: P. falciparum, P. vivax, P. malariae, and P. ovale.

What is the analytical sensitivity?

The kit detects parasitemia down to 50 parasites/µL for P. falciparum, exceeding WHO minimum performance criteria for malaria rapid diagnostic tests (RDTs).

Can fingerstick whole blood be tested bedside?

Yes. The test is specifically engineered for emergency bedside and travel clinic fingerstick screening.

What is included in each box?

25 individually wrapped cassettes, 25 capillary blood transfer pipettes, 1 bottle of lysis buffer, and package insert.

How to order for clinics and emergency departments in the UAE?

QuRapid provides emergency hospital stock and clinic distribution across Dubai and the UAE with rapid fulfillment.

Equip Your Clinic With QuRapid Malaria Pf / Pan Rapid Tests

Order CE-IVD certified Malaria Pf / Pan Rapid Test Kits with same-day dispatch across Dubai, Abu Dhabi, and the UAE. Wholesale institutional pricing available for emergency departments, travel clinics, and diagnostic laboratories.

Request Quotation