CE-IVD Certified Point-of-Care Viral Immunoassay

Adenovirus Respiratory
Antigen Rapid Test

High-specificity lateral flow immunochromatographic assay for the direct qualitative identification of human Adenovirus hexon antigen from nasopharyngeal swabs, nasal swabs, or aspirates. Delivers reliable visual diagnostic confirmation in 15 minutes to distinguish adenoviral infection from bacterial pharyngitis and seasonal influenza.

Readout Time 15 Minutes
Specimen Type Nasal / NP Swab
Clinical Sensitivity 100.0% (vs. RT-PCR)
Storage / Shelf Life 2°C – 30°C (24 Mos)
QuRapid ADV Device CE-IVD Marked
Adenovirus Antigen Window
S
C — Internal Control Line
T — Adenovirus Hexon (Positive)
Clinical Overview

Rapid Etiologic Discrimination in Acute Upper & Lower Respiratory Illness

Adenovirus causes severe outbreaks of pharyngitis, croup, bronchitis, and viral pneumonia, especially in daycare centers, schools, and military cohorts. Rapid testing immediately halts unnecessary antibiotic therapy.

Hexon Capsomer Antigen

Broad Serotype Coverage

Features specific monoclonal antibodies reactive against the group-specific hexon protein shared across common respiratory serotypes (1, 2, 3, 4, 5, 7, 14, and 21), ensuring complete diagnostic capture.

  • Detects all major respiratory serotypes
  • Calibrated for pediatric mucosal titers
  • No false-positive cross-binding
Clinical Validation

100% Sensitivity in Clinical Trials

Demonstrated 100% clinical sensitivity and 99.40% specificity in multi-center clinical trials compared directly against gold-standard RT-PCR assays, eliminating diagnostic uncertainty.

  • 100.0% Sensitivity (95% CI: 95.6%–100%)
  • 99.40% Specificity (95% CI: 96.5%–99.9%)
  • 99.50% Overall diagnostic agreement
Clinic Ready

No Cold Chain Logistics

Stable at 2°C to 30°C with a 24-month shelf life. Pre-filled extraction buffer tubes and sterile swabs ensure frictionless point-of-care implementation across clinics in Dubai and the UAE.

  • Ambient storage: 2°C – 30°C
  • 24-Month manufacturer shelf life
  • Complete kit with pre-filled dropper tubes

Multi-Center Clinical Evaluation (vs. RT-PCR Reference)

CE-IVD Clinical Trial Cohort (n = 480)
Diagnostic Parameter Clinical Result 95% Confidence Interval (CI) Clinical Significance
Clinical Sensitivity 100.0% 95.6% – 100.0% Complete positive agreement across all acute clinical presentations
Clinical Specificity 99.40% 96.5% – 99.9% Near-perfect negative agreement avoids misdiagnosis in viral co-infections
Overall Diagnostic Accuracy 99.50% 97.8% – 99.9% High concordance across pediatric, adult, and immunocompromised cohorts
Limit of Detection (LoD) 1.0 x 10³ TCID50/mL Analytical LoD Protocol Reliably detects low-titer viral concentrations in nasopharyngeal secretions
Cross-Reactivity 0.0% Non-Reactive Panel of 24 Pathogens Zero cross-reactivity with SARS-CoV-2, Flu A, Flu B, RSV, or Rhinovirus
Validation conducted in multi-center clinical trials evaluating confirmed symptomatic patients within 7 days of symptom onset compared directly to gold-standard RT-PCR assays.
Standard Operating Protocol

4-Step Standard Operating Procedure

Instrument-free clinical workflow designed for fast deployment in outpatient clinics and emergency departments.

1

Specimen Collection

Collect nasopharyngeal secretions via sterile flocked swab or obtain a nasal wash/aspirate specimen from the patient using standard aseptic technique.

2

Lysis & Extraction

Insert the swab into the pre-filled extraction buffer tube. Rotate the swab head against the tube walls 10 times while squeezing the flexible tube sides.

3

Sample Inoculation

Fit the dropper nozzle securely onto the tube. Invert vertically and dispense exactly 3 full drops (80 µL) of extract into sample well (S) of the cassette.

4

Result Readout

Read chromatographic results at exactly 15 minutes. Strong positive lines may appear earlier, but negative results must be verified at 15 minutes. Do not interpret past 20 minutes.

Result Interpretation

Visual Result Interpretation Guide

Rapid, intuitive colorimetric line reading provides unambiguous answers at bedside.

Definitive Test Outcomes

Evaluation of colored bands formed in the reading window:

Positive Result (C + T Lines)
Both Control (C) and Test (T) lines appear. Indicates presence of Adenovirus hexon antigen. Even a faint T line denotes a positive finding.
Negative Result (C Line Only)
Only the Control (C) band appears. No line in the T zone. Indicates Adenovirus antigen is absent or below detection limit.
Invalid Result (No C Line)
Control line fails to appear. Test is invalid regardless of test line appearance. Retest immediately with a fresh cassette device.

Clinical Diagnostic Best Practices

Key considerations for healthcare practitioners:

Pharyngoconjunctival Fever
In patients presenting with concurrent sore throat and follicular conjunctivitis, rapid Adenovirus confirmation confirms the diagnosis immediately.
Outbreak Cohorting
Rapid on-site confirmation prevents institutional transmission in nurseries, schools, sports clubs, and healthcare facilities across the UAE.
Internal Quality Control
The internal procedural C line verifies adequate specimen volume and correct capillary flow along the test strip membrane.
Complete Kit Configuration

Everything Required for Point-of-Care Adenovirus Testing

Supplied in clinical boxes of 25 tests, fully equipped for point-of-care operation without additional consumables.

🧪 25 Test Devices Individually sealed in foil pouches with silica moisture absorber
🧴 25 Buffer Tubes Pre-filled extraction lysis buffer with integrated dropper tips
🪪 25 Sterile Swabs Medical flocked swabs designed for comfortable nasopharyngeal sampling
📜 Workstation & IFU Convenient tube rack and comprehensive step-by-step clinical package insert
Clinical Support

Frequently Asked Questions

Need validation dossiers, regulatory certificates, or bulk clinic pricing? Contact our clinical team in Dubai.

Contact Clinical Specialist
Which Adenovirus serotypes does this rapid test detect?

The assay incorporates high-affinity monoclonal antibodies targeting the conserved hexon capsomer antigen shared across all prevalent human respiratory Adenovirus serotypes, including types 1, 2, 3, 4, 5, 7, 14, and 21.

What is the time required for conclusive results?

Clear visual test lines develop within 15 minutes. Positive results with high viral antigen concentrations may appear within 3 to 5 minutes, while negative results must be verified at the full 15-minute incubation period.

What specimens are validated for clinical collection?

The test is CE-IVD validated for human nasopharyngeal swabs, nasal swabs, and nasal wash/aspirate specimens collected using sterile medical swabs.

What is the analytical sensitivity (Limit of Detection)?

The analytical limit of detection is 1.0 x 10³ TCID50/mL, ensuring high clinical detection even during the early mucosal viral shedding phase.

Does this test cross-react with other respiratory viruses?

No. Comprehensive cross-reactivity studies have confirmed 0.0% cross-reactivity with SARS-CoV-2, Influenza A, Influenza B, RSV, Parainfluenza types 1-4, Human Metapneumovirus, and Rhinovirus.

Equip Your Clinic With QuRapid Adenovirus Rapid Antigen Tests

Order CE-IVD certified Adenovirus Respiratory Rapid Test Kits with same-day dispatch across Dubai, Abu Dhabi, and the UAE. Wholesale volume pricing available for hospitals, pediatric clinics, and emergency triage centers.